4.3.3 Setting Propped
Door Output Time
Command #44 lets you set the Propped Door Output
time.
1. Place the prox.pad plus unit in Program mode.
Press:
99 # Master Code * (default is 1234)
A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.
2. To program the Aux relay for Propped Door, enter
the following on the keypad:
10#3#2#**
3. Enter the desired Propped Door O utput time. For
example:
44#ttt#0#**
where, ttt=propped door time, to nearest 10’s
seconds, entered as 10-990; default=30 seconds.
4. Press * to exit Program mode.
4.3.4 Setting Forced
Door Output Time
Command #45 lets you set the Forced Door Output
time.
1. Place the prox.pad plus unit in Program mode.
Press:
99 # Master Code * (default is 1234)
A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.
2. To program the Aux relay for Forced Door, enter
the following on the keypad:
10#4#2#**
Chapter 4: Programming 4.3 Programming Outputs