4.2.5 Batch Load
Cards Manually
(without presentation)
“Batch entry” allows you to enter multiple, sequential
26-bit HID cards into the prox.pad plus unit’s memory
at one time. (Keeping IEI proximity cards in order is
easyasthecodeisprintedonthefrontofeachcard.)
NOTE: The facility code must be programmed into
theunitbeforeanybatchentrycanoccur.Thefacility
code MUST be programmed only once. The default
facility code is 11. For the programming sequence
used to enter the 3-digit facility code, see command
32, parameter 4 (see table in section 4.6).
To add several users from the proximity reader, follow
this procedure:
1. Place the prox.pad plus unit in Program mode.
Press:
99 # Master Code * (default is 1234)
A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.
2. On the prox.pad plus keypad, press:
57 # (total number of cards to be added) #
(starting user location) # card number *
repeat card number *
NOTE: Never enter one (1) or (2) as the starting user
location since they are reserved for the Master code
and Supervisor code, respectively.
3. On the prox.pad plus keypad, press * to exit Pro-
gram mode.
Up to 1998 users can be added this way at one
time. (User 1 is reserved for the Master code, User
2fortheSupervisorcode.)
Chapter 4: Programming 4.2 P rogramming Users
4-14 prox.pad plus Install/Program. Manual, PPP, D2