User manual of EC160 elevator intelligent integrated machine Fault code
211
43 76
Forced DEC
switch faulty
action
Up forced
deceleration
switch faulty
action when the
elevator goes up;
down forced
deceleration
switch faulty
action when the
elevator goes
down
Switch damage or
disconnection
Emergency
deceleration to
leveling; fault
reset
automatically
44 77
Terminal
overspeed
running
When the
elevator runs to
the terminal and
the forced
deceleration
switch acts, the
speed exceeds
the
corresponding
speed of the
switch
Switch damage or
disconnection
Stop
immediately;
fault reset
manually
45 79
Abnormal
elevator
position
1.The elevator is
in the terminal
station, but the
corresponding
low speed forced
deceleration
switch does not
act
2.The
corresponding
low speed forced
deceleration
switch acts, but
1.Disconnection or
short circuit of the
low speed forced
deceleration
switch
2.High speed
counting pulse
and door area
signal loss
3.Check the wire
rope
4.Check the
corresponding
Preferred
leveling,
fault reset
automatically

Table of Contents