EasyManua.ls Logo

INVT EC160

INVT EC160
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual of EC160 elevator intelligent integrated machine Function parameters
84
Function
code
Instruction Setting rangedefault value Remarks
P2_00 Motor type selection 0-11
Not modify
in running
Select the motor type
0: Asynchronous master
1: Synchronous master
After changing the motor type, it needs to change the corresponding
parameters of the encoder. When the synchronous changes into
asynchronous motor, P2_06~P2_10 will match according to the rated
power of the motor.
Function
code
Instruction Setting rangedefault value Remarks
P2_01 Rated power of the motor 0.1~150.0kW7.5
Not modify
in running
P2_02 Rated frequency of the motor 3Hz~400Hz27.8
P2_03 Rated speed of the motor 0~30000rpm167
P2_04 Rated voltage of the motor 0~460V380
P2_05 Rated current of the motor 0.1~1000.0A15
Input above parameters correctly when master autotuning. After modifying the rated power of the
asynchronous, P2_06~P2_10 will match according to the rated power of the motor.
Function
code
Instruction Setting rangedefault value Remarks
P2_06 Resistance of the stator 0~65.5351.41
Not modify
in running
P2_07 Resistance of the rotor 0~65.5351.41
P2_08
Inductance of the stator and
rotor
0~6553.5mH141
P2_09
Mutual inductance of the stator
and rotor
0~6553.5mH140
P2_10 Current without load 0~655.35A1.5
Above parameters will update automatically after autotuning of the master. These parameters are

Table of Contents

Related product manuals