User manual of EC160 elevator intelligent integrated machine Function parameters
81
Function
code
Instruction Setting rangedefault value Remarks
P1_03
Reducing deceleration 1 (fast
deceleration at the beginning
stage)
0.001~9.999m/s
3
0.350
P1_04
Reducing deceleration 2 (fast
deceleration at the beginning
stage)
0.001~9.999m/s
3
0.350
P1_05 Deceleration speed 0.001~9.999m/s
2
0.700
The set acceleration speed or deceleration speed cannot exceed 3
times of the corresponding increasing acceleration or reducing
deceleration.
Figure 6-1 Parameters diagram of S curve
Function
code
Instruction Setting rangedefault value Remarks
P1_06 Door area 100~999200
Not modify
in running
If the total floor3, parameter P1_06 can measure the door area
(length) by hoistway autotuning. If the total floor=2, set the value
manually according to the actual situation. Before fast debugging
leveling, the precision can be adjusted by modifying the parameter.
After hoistway autotuning or save, the value is limited less than 400
automatically.