Goodrive18 series two-in-one VFD Function parameters and function terminal reuse
-35-
10% for each increase of 1k carrier frequency.
Setting range: 1.0–15.0kHz
Motor parameter
autotuning
0: No operation
1: Rotary autotuning
Comprehensive motor parameter autotune
It is recommended to use rotating autotuning
when high control accuracy is needed.
2: Static autotuning 1 (autotune totally). It is
suitable in the cases when the motor cannot be
de-coupled from the load.
3: Static autotuning 2 (autotune some
parameters only including P02.06, P02.07, and
P02.08).
0: Invalid
1: Valid during the whole procedure
The auto-adjusting function of the VFD can
eliminate the impact on the output voltage of the
VFD because of the bus voltage fluctuation.
Function
parameter
restoration
0: No operation
1: Restore to default values
2: Clear fault records
3: Lock all function codes
4: Apply the music fountain function
Note: The function code is restored to 0 after
finishing the selected function operation.
Use this function with caution since restoring to
default values will clear the user password.
P01 Start and stop control
0: Direct start. Start at the starting frequency
P01.01.
1: Start after DC braking. Start the motor at the
starting frequency after DC braking (setting the
parameter P01.03 and P01.04). It is suitable in
the cases where reverse rotation may occur to
the low inertia load during starting.
2: Reserved
3: Reserved