Hardware Description and Installation Manual Issue 1.3
88
Figure 7.3.4-1 LDP-7048DSS Console install
The LDP-7048 DSS Console is wired as a normal Digital Key Telephone to a separate
digital port of the eMG80, refer to Section
LDP-7048 DSS Console Wiring
7.3.1.
LIP-8000/8000E Series DSS/BLF Console is available in three (3) models 12 button
w/paper labels (LIP-8012DSS), 12-button w/LCD (LIP-8012LSS), and 48-button w/paper
labels (LIP-8048DSS). Up to four (4) consoles can be connected to LIP-8000/800E series
phone using the serial ribbon cable from the console. LIP-8000 phones will power a
maximum two (2) LCD DSS Consoles and, when more than two consoles are connected,
one must be the 48-button Console. In all cases, the 48-button Console must be powered
by the AC/DC Adaptor-K. The figures below depict installation of various console
configurations. Note that in all cases, AC/DC Adaptor-K is attached to the 48-button
Console.
LIP-8000 Console Installation and Wiring

Table of Contents