Manual No. 085-3435-07 23/45 IGB/IGX Series (Overseas Specifications) Service Manual
Address Weight Item Data
112A - Start width 0: ±1/50 (±2%) of weighing capacity
1: ±1/25 (±4%) of weighing capacity
2: ±1/10 (±10%) of weighing capacity
3: ±1/7.5 (±13.3%) of weighing capacity
4: ±1/6 (±16.6%) of weighing capacity
5: ±1/5 (±20%) of weighing capacity
6: ±1/4 (±25%) of weighing capacity
7: ±1/3 (±33.3%) of weighing capacity
8: ±1/2 (±50%) of weighing capacity
9 and more: Invalid
112B - Stable/Re-stable count 0 through 15 times
113A - Stable/Re-stable width n=0 through 15 (±n/10 e)
113B - Re-stable operation start
width
n=0 through 15 (±n/10 e)
1 Zero point mark 0: Light at true zero 1: Light at dummy zero
2 Over-scale display 0: Blank 1:”OL”
4 Display below true zero 0: “-----------“ 1: Minus numeric value
114A
8 Decimal point form 0: ”.” 1: ”,”
1 Over-scale range 0: Display upto +9e 1: Display upto +3e
2 Tare subtraction 0: Yes 1: No
4 Tare clear with ZERO key 0: No 1: Yes
114B
8 Zero supress display
(Multi Interval
specification only)
0: Yes 1: No
1 Key-in preset tare
subtraction and preset
single weight function
Preset unit weight
function
0: Yes 1: No
2 Zero tracking 0: Yes 1: No
4 Micro weight follow-up 0: Yes 1: No
115A
8 Unstable width 0: ±0.5e 1: ±20e
1 No. of PLUs and PLU
display (IGB only)
0: 10 PLUs 1: 5 PLUs
Display No display
2 Stable display
(IGB only)
0: “∗” display 1: “▼” cursor display
4 Weight unit cursor display 0: Always light 1: Light only when “No change”is set
115B
8 Reserved