Chapter 4 REFERENCE DATA
INS-100 Service Manual No. 085-6692-09 33
4.2 Weighing Condition Setting Table (D008A)
Address No. Data Content Data Range
1
2
1 Weight decimal point position 0: 0 1: Invalid
2: 0.00 3: 0.000
4
110A
8
2 Minimum display 0: 1 4: 2
8: 5 C: Invalid
110B - 0 Accuracy (Resolution) 0 - F: Invalid (1/3000 fixed)
1
2
4
4 Changing method 0-2: Single range
(Price calculation spec.)
3: Single range
(Price calculation spec. Unit price 4 digits)
4-7: Single range
(Weight display only spec.)
111A
8
1
5 Weight unit
(Invalid in current software)
0+0: kg 8+0: g
0+1: lb 8+1: oz
2
4
111B
8
6 Filter setting
(Invalid in current software)
0, 2, 4, 6, 8, A, E: Invalid
112A - 7 Start width 0: ±1/50 (±2%) of weighing capacity
1: ±1/25 (±4%) of weighing capacity
2: ±1/10 (±10%) of weighing capacity
3: ±1/7.5 (±13.3%) of weighing capacity
4: ±1/6 (±16.7%) of weighing capacity
5: ±1/5 (±20%) of weighing capacity
6: ±1/4 (±25%) of weighing capacity
7: ±1/3 (±33.3%) of weighing capacity
8: ±1/2 (±50%) of weighing capacity
9 - F: Invalid
112B - 8 Stable/Re-stable frequency 0-15 times
113A - 9 Stable/Re-stable width n=0 -15 (±n/10 e)
113B - 10 Re-stable operation start width n=0 -15 (±n/10 e)
114A 1 11 Auto power save function 0: Operation allowed 1: Operation prohibited
2 12 Over scale display 0: BLANK 1: "OL"
4 13 Less than true zero display 0: "-----------" 1: Minus numeric value
8 14 Decimal point shape 0: Invalid 1: Invalid
114B 1 15 Zero key during tare subtraction 0: Enabled 1: Disabled
2 16 Tare subtraction 0: Enabled 1: Disabled
4 17 Tare weight clear with Zero key 0: No 1: Yes
8 18 Unnecessary zero display
suppression
0: Invalid 1: Invalid
115A 1 19 Manual tare entry function 0: Enabled 1: Disabled
2 20 Zero tracking 0: Function provided 1: Function not provided
4 21 Minute weight follow operation 0: Function provided 1: Function not provided
8 22 Unstable width 0: ±0.5e 1: ±20e
115B 1
2
23 Price decimal point position 0: 0 1: 0.0
2: 0.00 3: 0.000
4
8
24 Price calculation 0: No processing
4: 5 step (0, 5, 10, 15  )
8:10 step (0, 10, 20, 25  )
C: 25 step (0, 25, 50, 75  )
116A 1 26 Unit price 0: 1kg (1lb) 1: 100g (0.1lb)
2 27 Price fraction processing 0: Half-adjust 1: Round-down
4 28 Price display in instability 0: Display 1: No display
8 29 Reserve
116B 1 30
Allow accumulate
0: No 1: Yes
2 31 Reserve
4 32 Reserve
8 33
Special Price calculation
0: No 1: Yes