Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 67
Accuracy
±(0.05%+0.05%FS)
Read-back
power
Range
10KW
Resolution
1W
Accuracy
±(0.2%+0.2%FS)
Protection range
Overpower
protection
≒10.1KW
Overcurrent
protection
≒11A ≒110A
Overvoltage
protection
≒850V
Overtemperatur
e protection
≒85℃
Specification
Short circuit
Current (CC)
≒11A ≒110A
Voltage (CV)
0V 0V
Resistance
(CR)
≒30mΩ ≒30mΩ
impedance
2MΩ
12U
Model IT8831 IT8832
Rated value
( 0-40 °C)
Input voltage
0~120V 0~120V
Input current
0~75A 0~750A 0~100A 0~1000A
Input power
15KW 20KW
voltage
0.15V/75A 1.5V/750A 0.15V/100A 1.5V/1000A
Constant
voltage
mode
Range
0.1~18V 0.1~120V 0.1~18V 0.1~120V
Resolution
1mV 10mV 1mV 10mV
Accuracy
±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant
current
mode
Range
0~75A 0~750A 0~100A 0~1000A
Resolution
1mA 10mA 10mA 100mA
Accuracy
±(0.1%+0.1%FS) ±(0.1%+0.1%FS)
±(0.2%+0.1%F
S)
Constant
resistance
mode *1
Range
0.005Ω~10Ω 10Ω~7.5KΩ 0.005Ω~10Ω 10Ω~7.5KΩ
Resolution
16bit 16bit
Accuracy
*2
0.01%+0.0008S
*2
0.01%+0.0008
S
Constant
power
Mode *3
Range
15KW 20KW
Resolution
1W 1W
Accuracy
0.2%+0.2%FS 0.25%+0.25%FS
Measuring range