Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 70
Constant
power
Mode *3
Range
15KW 20KW
Resolution
1W 1W
Accuracy
0.2%+0.2%FS 0.2%+0.2%FS
Measuring range
Read-back
voltage
Range
0~50V 0~500V 0~50V 0~500V
Resolution
1mV 10 mV 1mV 10 mV
Accuracy
±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range
0~30A 0~300A 0~40A 0~400A
Resolution
1mA 10mA 1mA 10mA
Accuracy
±(0.05%+0.05%FS) ±(0.05%+0.1%FS)
Read-back
power
Range
15KW 20KW
Resolution
1W 1W
Accuracy
±(0.2%+0.2%FS) ±(0.2%+0.2%FS)
Protection range
Overpower
protection
15.1KW
20.1KW
Overcurrent
protection
33A 330A 44A 440A
Overvoltage
protection
530V 530V
Overtemperat
ure
protection
85 85
Specification
Short circuit
Current (CC)
33A 330A 44A 440A
Voltage (CV)
0V 0V 0V 0V
Resistance
(CR)
8mΩ 8mΩ 6mΩ 6mΩ
Input
terminal
impedance
1MΩ
1MΩ
Dimension
27U
Model IT8833B IT8834B
Rated value
( 0-40 °C)
Input voltage
0~500V 0~500V
Input current
0~50A 0~500A 0~60A 0~600A
Input power
25KW 30KW
Min. operating
voltage
0.25V/50A 2.5V/500A 0.3V/60A 3V/600A
Constant
voltage
mode
Range
0.1~50V 0.1~500V 0.1~50V 0.1~500V
Resolution
1mV 10mV 1mV 10mV
Accuracy
±(0.025%+0.05%FS) ±(0.025%+0.05%FS)
Constant
current
Range
0~50A 0~500A 0~60A 0~600A
Resolution
1mA 10mA 1mA 10mA

Table of Contents

Other manuals for ITech IT8800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8800 Series and is the answer not in the manual?

ITech IT8800 Series Specifications

General IconGeneral
BrandITech
ModelIT8800 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals