Function and Features 
  Copyright © ITECH Electronic Co., Ltd.  13 
 
 
 
Fig. 3-1 Voltage-Current Relation Schema under CC Mode 
 
Under CC mode, the electronic load provides three ways to set constant 
current. 
  Rotate adjusting knob to set constant current value. 
  Use numeric keys to input current value and press [Enter]  key to 
confirm set constant current value. 
  Use 
  moving cursor and press  to adjust values at 
corresponding positions. 
Operation steps 
1.  Press [CC] key and [Shift] +[CV] to enter parameter setting screen. 
Constant   Current 
Range=0.000A 
2.  Set maximum working current value and press [Enter] for confirmation. 
Constant   Current 
Range =1.000A 
3.  Set maximum voltage value and press [Enter] key. 
Constant   Current 
High=0.00V 
4.  Set minimum voltage value and press [Enter] key. 
Constant   Current 
Low=0.000V 
5.  Set high and low rate and press [Enter] key. 
Constant   Current 
High-Rate  Low-Rate 
6.  Set ascending slope and press [Enter] key. 
Constant   Current 
Rise up=0.000A/uS 
7.  Set descending slope and press [Enter] key. 
Constant   Current 
Rise down=0.000A/uS 
8.  Complete parameter setting. 
10.0000V   0.0000A 
0.00W     CC=1.000A 
 
Load voltage