Function and Features 
  Copyright © ITECH Electronic Co., Ltd.  16 
3.2.4 Constant power operation mode (CW) 
Under CW mode, the electronic load will consume a constant power, as shown 
below. If input voltage rises, the input current decreases and power P (= V * I) 
will maintain at setting power. As shown in Fig. 3-4. 
 
 
Fig. 3-4 Voltage-Current Relation Schema under CW Mode 
 
Under CW mode, the electronic load provides three ways to modify constant 
power. 
  Rotate adjusting knob to set constant power value. 
  Use numeric keys to input power value and press [Enter] key to confirm set 
constant power value. 
  Use 
  moving cursor and press    to adjust values at 
corresponding positions. 
Operation steps 
1.  Press [CW] key and [Shift] + [CV] to enter parameter setting screen. 
Constant   Power 
Range=400.00W 
2.  Set maximum working power value and press [Enter] for confirmation. 
Constant   Power 
Range =300.00W 
3.  Set maximum voltage value and press [Enter] key. 
Constant   Power 
High=130.00V 
4.  Set minimum voltage value and press [Enter] key. 
Constant   Power 
Low=0.000V 
5.  Complete parameter setting. 
10.0000V   0.0000A 
0.00W    CW=1.00W 
 
NOTE 
If the above method is for editing auto test step (as mentioned below), constant 
power range can also be set.