EasyManuals Logo

ITRON Intelis Gas Meter User Manual

ITRON Intelis Gas Meter
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Warning! The automatic high flow valve closure will not operate if the meter is in an
unrecoverable error state. This includes: Flow Meas. Hard fail., Flow Sens. Meas.
Error, and/or Transducer Error.
LCD alarm Description
Reverse Flow detect. The meter is currently
detecting reverse flow; gas flowing from outlet to
inlet.
The reverse flow event is an alarm for utilities
that alerts them of possible tampering. If a
reverse flow is detected, the meter may be
installed backwards. The Reverse Flow detect.
alarm is cleared once normal flow and a small buf-
fer of 0.71 CF (0.02 m3 or 20L) is reached. This
alarm has a start and end log.
Ext. High Flow detect. The meter detected flow
that exceeded the utility-configurable high flow
threshold. This alarm has a start and end log.
High Temp. detect. The meter detected that the
temperature exceeded the utility-configurable
high temperature threshold.
Note: Setting the temperature threshold to C
(32°F) will disable the high temp detection. In this
situation, if high temperature shutoff is enabled,
the valve won't shutoff. This alarm has a start
and end log.
Table 3LCD display alarms and description
11 December 2019 TDC-1782-005 23
Intelis Gas Meter Installation Guide 4 LCD Operation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON Intelis Gas Meter and is the answer not in the manual?

ITRON Intelis Gas Meter Specifications

General IconGeneral
BrandITRON
ModelIntelis Gas Meter
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals