LCD alarm Description
Flow Meas. Hard fail. The meter detected that
the flow measurement sensor failed. This con-
dition is an unrecoverable error. Remove the
meter and return it to Itron for evaluation. This
alarm has a start log.
Flow Meas. OOR detect. The meter detected
flow that is outside the physical range of 500
CFH (14.2 m3/h) of the measurement sensor.
This alarm has a start and end log.
Gas temp OOR detect. The meter detected that
the maximum (133° F/56° C) or minimum (-31°
F/-35° C) temperature range was exceeded. This
is a recoverable error. This alarm has a start and
end log.
Flow Sens. Meas. Error The meter detected that
a flow sensor measurement error occurred. This
is an unrecoverable error. Remove the meter and
return it to Itron for evaluation. This alarm has a
start log.
Transducer Error. The meter detected that its
ultrasonic transducers experienced an error. This
is an unrecoverable error. Remove the meter and
return it to Itron for evaluation. This alarm has a
start log.
Table 3LCD display alarms and description (continued)
Additional LCD Screen Displays
The LCD displays two additional screens in an overflow or test event.
■
Overflow. This screen displays if the meter reaches an overflow condition.
■
Display test. This screen displays after a long button press of 4.8 seconds. The test