Important! If Itron, Actaris, Sprague, or other is listed, it is still necessary to add a
new manufacturer name specifically for the Intelis Gas Meter. Itron suggests using
ITRON-RTY following the steps listed below. The MFR Type must have the RTY
suffix to allow setting and saving the revs desired for any given test and flow rate.
Without the RTY suffix, the settings will not be saved.
7. Select Meter_Table checkbox.
This step allows you to copy an existing meter setup and modify it to create the new Intelis
Gas Meter (for example, choose I-250, Itron). Select a similar meter's row. Follow the Meter-
Table instructions: Click on the next open/empty row. To complete the addition, click off of
the table and select Add Chosen Meter. The following illustration shows the successful copy
of the I-250 meter to create the Intelis 250 MeterName, ITRON-RTY MeterMfr.
11 December 2019 TDC-1782-005 35
Intelis Gas Meter Installation Guide 5 îProving