9.3 Basic Drive Display
Status LED - green
Constant Motor stopped (Standby)
Blinking Motor run
Error LED - red
The type of error is indicated by the number of blinks of the red ERROR LED.
1 blink Undervoltage
2 blinks Overcurrent / Overload
3 blinks Drive thermal overload
4 blinks Overvoltage
5 blinks Code Error
6 blinks Motor thermal overload (external contact is open)
For detailed information see chapter 11 Failure messages.
9.4 Software parameters
In the following chapters all parameters of the main menu and submenus are listed. The upper
window shows the factory setting and the line below the possible range of settings. The general
parameter description is written for the HYDROVAR Master Inverter (Full featured HYDROVAR including
the high level control card which also supports the optional modules like the optional Relay Card and all
specific software features).