Page 5-24 ITW Dynatec
Revised 1/16 V6 DCL Touch Screen Controller for Dynamelt M & D ASUs
Heating Priority Screen
To go to this screen, press the Heating Priority button on the Settings Screen.
This screen allows you to set a Heating Priority for each zone. Heating Priority allows the hopper
zones to heat to their ready temperatures before the other zones begin heating. In this way, the
larger mass of adhesive in the hopper zones (including the grid, hopper and filter block) gets a
head start on the other zones (hoses, applicators and auxiliary zones).
Heating Priority Matrix Example:
Item Description
1
Touch each zone field to select one of the following three Heating Priorities, or to switch the
zone OFF:
PRIO1 = the zone will heat first.
PRIO2 = the zone will begin to heat after the PRIO1 zones have reached their setpoints.
PRIO3 = the zone will begin to heat after the PRIO2 zones have reached their setpoints.
OFF = the zone is OFF. It will not heat and it will not be displayed on the Main screen.
2 Press the OK button to confirm your entered values and return to the previous screen.
3 Press the ESC button to discard any non-confirmed values and return to the previous screen.
4
Press the Standard Sequence button to accept the following standard Heating Priorities:
PRIO1 = grid, hopper and filter block
PRIO2 = hoses
PRIO3 = applicators and other auxiliary components
Press the OK button to confirm.
5
Press the Without Sequence button to assign all zones to PRIO1. With this setting, all zones
will begin to heat after turning on the unit. Press the OK button to confirm.