ITW Dynatec Programming Page 5-33
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Level Control Settings
To go to this screen, press the General Settings button on the Settings Screen.
If Digital Level Sensor is installed:
Item Description
1
Parameter Selection tabs
The Level Control Settings tab has been selected.
2
• This is a programmable time delay for reappearance of the level control’s Empty message.
The level control device informs the operator via a "Minimum Level" message on the display
that the hopper needs to be refilled. After expiration of the time delay, the message
Minimum Level will be indicated on the display. The programmable range is 0-31 minutes.
• Touch a zone input box and a numeric entry keypad will appear and the values can be
edited. Enter the value and confirm by pressing OK.
3 Press the left-pointing arrow to go to the previous General Settings screen.
4 Press the right-pointing arrow to go to the next General Settings screen.
5 Press the OK button to confirm your entered values and return to the previous screen.
6 Press the ESC button to discard any non-confirmed values and return to the previous screen.