ITW Dynatec Programming Page 5-7
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Temperature Zones Set Screen
To go to this screen, press the Set/Act button on the Main Screen.
The Set screen allows you to program the setpoint temperature for each activated zone. Each
zone requires a temperature setpoint.
When a temperature zone is not used, it can be deactivated (turned OFF) on the Heating Priority
screen. A zone that is turned Off no longer heats and is not monitored by the controller for over or
under temperatures.
Item Description
1
Set values
Display of the temperature setpoint values.
To edit values: Touch a zone input box and a numeric entry keypad will appear. Enter your
new setpoint value and confirm by pressing OK.
NOTE: Must be below the maximum setpoint value listed below.
The Set values are displayed for about 15 seconds and, if there is no display activity, the
display returns automatically to the Actual values.
The maximum setpoint value is 218°C (424°F).
See next page for Zone On/Off Switch on the Numeric Entry Keypad.