ITW Dynatec Programming Page 5-9
V6 DCL Touch Screen Controller for Dynamelt M & D ASUs Revised 1/16
Pump Overview Screen
To go to this screen, press the Pumps button on the Main Screen.
While on the Pump Overview Screen, all changes are immediate (you do not need to confirm).
The Pump Overview Screen allows you to program the pump mode (Manual, Stop or Automatic).
Each pump in the system must be programmed with a Pump Mode.
Decentralized pumps (e.g. Applicator, Metering Station: A plausible limit value of Input
Pressure (a minimum pressure of not less than 2 bar is recommended) has to be entered to avoid
a dry run of the pumps; otherwise the pump can be damaged. See point “Extended Pump Mode
Settings Screen, Linear Line Speed, Pressure Control” on next pages.
Item Description
1
Pump Overview
SETTINGS: Press Pump 1, Pump 2, etc. to go to the appropriate Pump Control screen.
MANUAL: The pump speed is adjusted manually by the ASU operator. When selected the
MANUAL icon is highlighted green.
STOP: The pump is stopped, until AUTO or MANUAL is selected. When selected, the
STOP icon is highlighted red.
AUTO: The pump speed is controlled via a 010VDC signal that is provided by an external
device (pattern control equipment or parent machine input). When selected, the AUTO icon
is highlighted green.
Auto operating parameters for each Pump must be set on the Pump Control Screen.
STATUS: Indicates if the pump is running or stopped.
RPM: The actual (calculated) RPM of each pump will be displayed.
PRESSURE: The pressure for each pump (if available) will be displayed. See explanation
under Main Screen point 4.
COMMENT = The entered pump name will be displayed.
2
1
3