Page 5-4 LCD Programming
Revised 11/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
Zone is cold
Zone is at lower tolerance
Zone is just under setpoint
Zone is exactly at setpoint
Zone is slightly above setpoint
Zone has a sensor fault
Zone is over‐heating
Zone is cold
Zone is near setpoint
Zone has
no sensor
(”solid”
bar‐graphs)
(”outlined”
bar‐graphs)
Bar‐Graphs
The temperature status of each zone is shown by a bar‐graph. A solid bar‐graph indicates that
the temperature zone is activated. An outlined bar‐graph indicates a temporarily de‐activated
temperature zone. A question mark indicates that the zone's RTD sensor is not valid. An ex clam ‐
ation mark inside a solid bar‐graph means that the temperature of the zone is significantly out ‐
side its setpoint window.
Scan Mode
Scan Mode allows the operator to watch the currently a ctive temperature zones scroll one at a
time on the Overview Screen. Each zone is displayed with its name, programmed setpoint, actual
temperature and bar graph.
To activate Scan Mode: On the Overview Screen, push the input knob.
To hold Scan Mode on one particular zone: push the input knob again.
To exit Scan Mode: Turn or push the input wheel.
Active Zones
Non‐Active
Zones