D15/D25/D45 V6 DC L ASU Manual #20-63
Installation Page 3-3
Revised 10/14
DANGER HIGH VOLTAGE
Disconnect and lock out input power to the application system before start-
ing any installation procedures. Make sure there is no electrical power on the
leads you will be connecting.
CAUTION: Grounding conductors never carry electrical current. The use of a neutral
conducting wire as earth ground is incorrect and may cause damage to the Dyna -
Control controller.
I
nstallation
Note: Re-read Chapter 1 “Safety Precautions” befo re performing any installation procedures. All
installation procedures must be performed by qualified, trained technicians.
After the D15/D25/D45 SERIES ASU has been properly mounted, the following general sequence
should be followed for installation:
1. Make sure that incoming line power to the ASU and that the unit’s Main Power Switch are
turned OFF.
2. Open the panel box door. Select correct plug for your ASU’s amperage (refer to instr uctions on
the following page). Run the power cord through the hole in the bottom of the base plate. In the
panel box, at the main circuit breaker, attach the power cord at the switch’s connectors. Attach
ground wire to ground lug provided in the base plate.
Filter Block Guard
Hose
Connectors
D25 ASU: Rear View
AUX
Connectors