Page 4-10 Controller Setup
Revised 10/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
LCD Controller Features
One-button Shortcuts
Press the “F” buttons to go to:
F1 = the Hopper temperature zone
F2 = the Hose temperature zone
F3 = the first Applicator temperature zone
F5 = toggle On/ Off
Shortcut to Advance to System Configuration Parameters
Press the System Configuration button (wrench button) on the Overview Screen once to advance to
the System Configuration parameters. Press it again, r epeatedly, to advance through the pages of
parameters.
Initial Heat-up Progress Bar
During heat up from a cold start, press the Input Wheel/ Knob for 5 seconds to see a progress bar
which graphically tracks heat-up until Ready status is attained and production can start. The scale
shown is 0% to 100% fully heated.
The ASU illustrated above is one-quarter heated.
If you would like to display the controller’s Scan Mode in order to watch the active temperature
zones scroll while the unit is heating, press the Input Knob once more.
Helpful Tips for the User
When the ASU is turned ON, all temperature setpoints and other operating parameters will be ex-
actly where they were w hen the ASU was turned off.
When the ASU is turned ON, all system heaters go ON u nless they have previously been de-activ-
ated (in which case they will be turned OFF) or if sequential heatups have been set. However, if
hopper temperature is above ready temperature when the ASU is turned on, all hose and head se-
quential heatups will be bypassed and hoses and heads will be turned ON.
Numeric Readout of Progress
HEAT UP HOLD
0100
25%
Progress
Bar