EasyManua.ls Logo

ITW Dynatec DYNAMELT D15 Series - Page 146

Default Icon
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 7-12 Troubleshooting
Revised 10/14
ITW Dynatec
D SERIES V6 DCL ASU Manuals
V6 Aux Power Module PN 115733
The V6 AUX module provides controlled power to the heater of the additional five zones. It re-
ceives its control signals from the V6 TEMP module. There are two of these modules on a D Series
ASU.
The fuses of the AUX Module are located underneath a protective cover. The cover should only be
removed after the ASU is switched Off and disconnected from the main power supply. After check-
ing or replacing fuses, the cover must be re-installed. All heater circuits are fused on both legs with
a 10A fuse. Always replace fuses with the same type of fuse. The maximum total load current of
the board is 40 Amps (20 per phase).
Connect to
V6 TEMP Module
Fuses (under
protective cover)
Head 4/6
Heater
Hose 4/6
Heater
Voltage Supply
from
Main Power Board
Head 3/5
Heater
Hose 3/5
Heater
Heater
Premelt Grid or
Filter Block

Table of Contents

Related product manuals