Seite 2 ITW Dynatec
Rev.6.15 Appendix Signal Isolator
Programming
Configuration by DIP-Switches
1) Open the suitable door on the side of the
device. Refer to TAB.1.
2) Set the input type by the dip-switch SW1 [1..4].
3) Set the output type by the dip-switch SW1
[6..8].
4) Set the options type by the dip-switch SW1 [5].
NOTE:
It is also possible to set the dip-switches using the wizard of the configuration software following the
procedure described in the section “Configuration by PC” until the step 6 and slicking on “Switch”.
DIP-Switch Configuration Tables
TAB.1 - Settings
NOTES:
* If the dip-switches SW1 [1..4] are all set in the position 0 (“Default”), the device will follow the
configuration programmed by PC (Input and output type and options).
* Eventual wrong dip-switches settings will be signalled by the blinking of the LED “PWR”.
Example of configuration:
)
Input 0 10 V
-
Options Direct
- Output 4 - 20 mA