Page 3-6 Installation
Revised 10/14
ITW Dynatec
D15/D25/D45 V6 D CL ASU Manual #20- 63
Terminal Circuit Location
‐‐ Input Power from Main Power 240VAC See terminal block, L1, L2, L3
PE Ground See terminal block, PE
‐‐ Input Power from Main Power, 380VAC See terminal block, L1, L2, L3
N Neutral, 380VAC See terminal block, N
PE Ground See terminal, PE
RELAY Terminal Block, see R1 R2
OUTPUT 1
RELAY Terminal Block, see A1 A2
OUTPUT 2
RELAY Optional
OUTPUT 3
ST.BY
IN-C.
Ready Output Signal
(contact closes when ready)
Alarm Output Signal
(contact opens when alarm)
Hopper Low Level Signal
(contact closes when glue level is low)
IN2
IN3
IN4
PU.ST.
Standby Input
Recipe Selection 1
Recipe Selection 2
Reserved
External Pump Start/Stop
(activate to start pump)
Common for Inputs
LINE
COM
G+I or L+I
Line Speed Tracking Voltage
(010V)
Line Speed Tracking Signal with
Signal Isolator (option)
Optional. Install at the left of the
Base Module. Refer to schematic
for details.
4. At installation, the customer must make the following terminal connections into the ASU’s
main power (ON/OFF) switch and modules. The modules do not need to be removed from the ASU
in order to make connections.
Refer to the detailed layout drawings of the components in Ch. 7 and/or the schematics in Ch. 11, if
needed.
Required connections for 380/400VAC, 3 phase, WYE ASU:
Required connections for 240VAC, 3 PH Delta ASU:
Nonessential connections; connect if feature is installed:
V6 BASE Module, bottom side:
V6 BASE Module, bottom side: