Manoeuvre programming
First program the safety elements (RadioSens3 or RadioBand3). Then program the maneuver.
Door MUST BE TOTALLY CLOSED before starting the manoeuvre programming.
Enter Installer mode: Press (KEEroll programming button), the maintenance indicator lights on, a beep will
be heard.
1-
Press , with the door
totally closed, on cover and
the control panel will initiate
and auto- programming
sequence.
7-
Autoclose time.
2-
Door opens 2 seconds.
8-
Press on cover and door
closes.
3-
Door closes automatically.
9-
Door stops.
4-
Door stops.
10-
Door opens automatically.
*Only with RadioSens3
5-
Door opens automatically.
11-
Door closes automatically.
*Only with RadioSens3
6-
Door stops.
12-
Maintenance indicator
lights off. End programming.
By default, RadioSens3 system adds an inhibition zone of maximum 4cm at the end of the closing movement.
It is possible to change the inhibition zone pushing on when the door is closing (step 11). From this point, RadioSens3
will be inhibited.
STOP button aborts the programming sequence.
jcmtechnologies
17