Maintenance
Enter Installer mode: Press (KEEroll programming button), the maintenance indicator lights on, a beep will
be heard.
The following functions can be done inside this maintenance mode.
Program maintenance manoeuvres
Maintenance warning: By entering Installer mode you can set the number of manoeuvres for the
maintenance warning.
Keep pressing to set up the maximum number of manoeuvres:
Frontal light Indication
1 flash 2.000 manoeuvres (default)
2 flashes 3.000 manoeuvres or one year
3 flashes 5.000 manoeuvres or one year
Reset manoeuvres counter
If the maximum number of movements is exceeded, the maintenance alarm lights on, by pressing there is
rapid blinking and the number of movements is adjusted to 0
Reset transmitters
Hold until and keys starts flashing,
a beep will be heard.
Without releasing , press to erase trans-
mitters, some beeps will be heard followed by a long beep.
jcmtechnologies
19