EasyManuals Logo

Johnson Controls TIWM018B22S User Manual

Johnson Controls TIWM018B22S
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
P5417089
5
3. Before Operation
Power is turned on. Apply power to the outdoor unit(s) at least 12 hours prior to operation of the
system for preheating of the compressor oil. Make sure that the outdoor unit is not covered with
snow or ice. If it is, remove it by using hot water that is approximately 122
o
F (50
o
C).
If the water temperature is higher than 122
o
F (50
o
C), it will cause damage to plastic parts.
Turn OFF the main power switch when the system is stopped for a long period of time.
If the main switch is not turned OFF, electricity is consumed because the oil heater is always energized
during compressor stopping.
When the system is started after a shutdown longer than approximately 3 months, it is recommended that
the system be checked by your service contractor.
NOTICE
3.2 Efcient Use of Indoor Unit
Do not leave a window or a door open.
The operating efciency is decreased.
It may cause condensation of the indoor unit. Ventilate a room sufciently.
Attach a curtain or a blind to a window.
Blocking direct sunlight into a room will increase efciency.
Do not use heat equipment during the cooling operation as much as possible.
The cooling efciency is decreased. It may cause condensation and dew drops.
Use a circulator if warm air stays around the ceiling.
Comfort increases. Contact your distributor for details for using a circulator.
Turn OFF the main power source if the indoor unit is not to be used for a long period.
The standby electricity charges will have to be paid even if the indoor unit is unused.
3.1 Operating Range
This heat pump air conditioner is designed for the following temperatures. Operate the heat pump air
conditioner within this range.
Temperature
Maximum Minimum
Cooling
Operation
Indoor 89
o
F DB/73
o
F WB (32
o
C DB/23
o
C WB) 69
o
F DB/59
o
F WB (21
o
C DB/15
o
C WB)
Outdoor 118
o
F DB (48
o
C DB) * 14
o
F DB (-10
o
C DB) *
Heating
Operation
Indoor 80
o
F DB (27
o
C DB) 59
o
F DB ( 15
o
C DB)
Outdoor 59
o
F WB (15
o
C WB) * -4
o
F WB (-20
o
C WB) *
DB: Dry Bulb, WB: Wet Bulb
* The temperature may change depending on the outdoor unit.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls TIWM018B22S and is the answer not in the manual?

Johnson Controls TIWM018B22S Specifications

General IconGeneral
BrandJohnson Controls
ModelTIWM018B22S
CategoryAir Conditioner
LanguageEnglish

Related product manuals