1.0 Quick Reference
The PowerSeries Pro Alarm System uses shortcut keys to access options or features on all models of
keypads. When using an LCD keypad, the PowerSeries Pro alarm system additionally uses a menu
based navigation system. Use the scroll keys to view the list of options contained within the current
menu.
NOTE: Some features must be enabled by the installer.
NOTE: Bypass Groups are not permitted in UL listed installations.
For SIA CP-01 classified installations, the Swinger Shutdown feature shall shut down the zone after a
programmable number of trips (the programmed default is 2). The zone is restored after a manual reset
by entering the access code at the time of disarming the alarm system, or it is reset automatically after 48
hours with no trips on any zones.
Status Lights
Function
Keys
Emergency Keys
Ready - Indicates system normal. Must be on to arm the sys-
tem. All zones must be secured or bypassed and the system
disarmed for this light to activate.
Stay
Arm
Fire Alarm
Armed- Indicates the system is armed. If the Ready light and
the Armed light are both on, an Exit Delay is in progress.
Away
Arm
Medical Alarm
Trouble - On indicates a system malfunction or tamper.
Flashing indicates that the keypad has a low battery con-
dition. Follow the instructions displayed or enter [*][2] to
view trouble. Correcting the trouble turns off the indicator.
Chime
Panic Alarm
AC Power - Indicates AC Power is present. The AC Power
light turns off when AC is absent.
Reset
Quick
Exit
Action Press
Away Arm
for 2 seconds + [Access Code†]
Stay Arm
for 2 seconds + [Access Code†]
Night Arm When armed in stay mode [*][1] + [Access Code†]
Disarm [Access Code]
No-Entry Arming [*][9] + [Access Code†]
Quick Arm /Quick Exit [*][0]
Cancel Arming Sequence [Access Code]
Bypassing - All bypass commands begin with [*][1] + [Access Code†]
Bypass Individual Zones [3 Digit Zone #]
Bypass All Open Zones [9][9][8]
Recall Last Bypass [9][9][9]
Clear Bypass
[0][0][0] OR [Scroll] Bypass Options + [*] + Clear Bypasses +
[*]
Program Bypass Group
[3 digit zone #s] + [9][9][5] OR [3 digit zone #s] + Bypass
Options + [*] + Prg Bypass Group + [*]
Load Bypass Group
[9][9][1] OR Bypass Options + [*] + [Scroll] Bypass Group + [*]
- 4 -