2.5.2.4 Serial Port Configuration (UART CONFIG)
The AlphaLine instrument is equipped with 4 serial ports (also called UART or COM).
The settings of the serial ports are divided over two screens as shown in Figure 35: UART Screen 1 on page 40 and
Figure 36: UART Screen 2 on page 40. Use the < or > button to toggle between the screens.
The default setting for NMEA (IEC 61162-1) data is 4800 baud, 8 databits, 1 stopbit. The default setting for Modbus over
serial port is 19200 baud, 8 databits, 1 stopbit and EVEN parity. See also Default Values AlphaLine Instrument on page
25.
Select and configure NMEA when a sensor is connected with the standard NMEA signals. Select ModbusMaster when
an interface (such as Analog Interface Mk.2 or AlphaTurn Interface Mk.2) is used.
Figure 35: UART Screen 1 Figure 36: UART Screen 2
1. In the MENU, touch the ADV SET button.
The PASSWORD screen appears.
2. Key in the password and confirm with the
button.
The ADVANCED SETTINGS MENU appears.
3. Touch the UART CONFIG button.
The UART screen 1 appears, see Figure 35: UART Screen 1 on page 40.
4.
Touch the + or – button to set UART from 0 to 3.
Touch the + or – button to set PARITY to ODD, EVEN, FORCED 0, FORCED 1, NONE.
Touch the + or – button to set STOP BITS to 1 or 2.
5. Touch the > button to toggle to screen 2, see Figure 36: UART Screen 2 on page 40 and follow the same principle
as for screen 1. Touch the < button to return to screen 1.
6. Touch the
button when the settings are correct.
7. If settings are modified, restart the instrument to initialize the serial port again.
40 | Operation