565
Alarm for New Target Acquired in Automatic Acquisition Zone (New Target)
The automatic acquisition function sets a zone in a range and issues an alarm when a new target (which is not
yet acquired) goes into this zone.
For the setting of an automatic acquisition zone, refer to “Automatic Acquisition [AUTO]” in Section 5.2.1
“Acquiring Target [ACQ].”
Alarm for New Target Acquired in Automatic Acquisition Zone
Status Symbol on display Alarm characters Alarm sound Conditions
New target in
automatic
acquisition zone
Red Blinking
New Target
Beep sound (pipi-pipi)
Alarm
acknowledgeable
The alarm is issued when a
new target is acquired in the
automatic acquisition zone.
Note:
When an already acquired target goes into automatic acquisition zone, the alarm message is
not displayed and the buzzer does not sound either.
12
In setting an automatic acquisition zone, it is
necessary to adjust the gain, sea clutter
suppression and rain / snow clutter
suppression to ensure that target echoes are
displayed in the optimum conditions. No
automatic acquisition zone alarms will be
issued for targets undetected by the radar, and
this may cause accidents such as collisions.
Caution

Table of Contents

Other manuals for JRC JMA-5212-4/6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5212-4/6 and is the answer not in the manual?

JRC JMA-5212-4/6 Specifications

General IconGeneral
BrandJRC
ModelJMA-5212-4/6
CategoryMarine Radar
LanguageEnglish

Related product manuals