757
7.5.5 Clear of Antenna Operation Time (TXRX Time CLR)
The system adds up the following operation time and contains it in the antenna unit:
x Transmission time
x Motor run time
Clear the above total time when the magnetron or antenna unit motor is replaced.
[I] Transmission Time Clear (TX Time Clear)
Clear the transmission time of the antenna unit.
Perform the following procedure to clear the transmission time when the magnetron is replaced.
Procedure 1 Hold down [RADAR MENU] key.
The Code Input Menu will appear.
2 Press [0] key.
3 Move the cursor onto the “ENT” button
in the Code Input menu, and press
[ENT] key.
The Adjust Menu will appear.
4 Press [2] key.
The Maintenance Menu will appear.
5 Press [6] key.
Press [2] key.
6. Select Yes in the Transmission Time Clear Confirmation Window.
The transmission time in the antenna's internal control circuit is cleared to 0.