7.5 MAINTENANCE MENU
758
7
yyy
yyyy
[II] Motor Run Time Clear (Motor Time Clear)
Clear the transmission time of the antenna unit.
Perform the following procedure to clear the transmission time when the magnetron is replaced.
Procedure 1 Hold down [RADAR MENU] key.
The Code Input Menu will appear.
2 Press [0] key.
3 Move the cursor onto the “ENT” button
in the Code Input menu, and press
[ENT] key.
The Adjust Menu will appear.
4 Press [2] key.
The Maintenance Menu will appear.
5 Press [6] key.
Press [3] key.
6. Select Yes in the Motor Run Time Clear Confirmation Window.
The motor run time in the antenna's internal control circuit is cleared to 0.