4-9  Section 4 Range and Bearing Measurement Methods 
 
 
 
APP A 
APP B 
 
 
 
 
4.5.1.2  Measuring with the [EBL] or [VRM] dial on the keyboard 
operation unit 
1 
Press the [EBL] dial. 
The context menu is displayed. 
2  By turning the dial, select either [EBL1 Control] or [EBL2 Control]. 
3  Press the [EBL] dial. 
If [EBL1 Control] is being selected, manipulation of EBL1 is enabled. 
If [EBL2 Control] is being selected, manipulation of EBL 2 is enabled. 
4  By turning the [EBL] dial, align the EBL with a target. 
The bearing of the target is displayed on the [EBL1] button. 
5  Press the [VRM] dial. 
The context menu is displayed. 
6  By turning the dial, select either [VRM1 Control] or [VRM2 Control]. 
7  Press the [VRM] dial. 
If [VRM1 Control] is being selected, manipulation of VRM1 is enabled. 
If [VRM2 Control] is being selected, manipulation of VRM2 is enabled. 
8  By turning the [VRM] dial, align the VRM with a target. 
The range of the target is displayed on the [VRM1] button. 
Bearing and range from the own ship's 
position to the target in this figure: 
 True bearing  45.0° 
 Range  0.30 NM