Section 4 Range and Bearing Measurement Methods  4-26 
4.6.7.2  Operation in [Individual] mode 
In [Individual] mode, the index line that is selected in the [Index Line] combo box is operated. 
 
[Using the [EBL] dial] 
By using the [EBL] dial, the bearing of the index line can be changed. 
 
Setting parallel index lines consecutively by using the [EBL] dial 
When [Sequential] is checked, the floating mode is set. When [Screen Fix] or [L/L Fix] is selected, the 
parallel index line to be set is switched in the sequence of Index Line1→2→•••→8→1•••, enabling 
consecutive setting. 
 
Memo 
The index lines that are set to be hidden by selecting [View] - [Tools] on the menu are skipped 
during operation. 
 
[Operating the [VRM] dial] 
By using the [VRM] dial, the interval of the index lines can be changed. 
The reference point for changing the interval can be an end point 1 or 2 of the index line or the 
reference point on the line. 
Whenever the [VRM] dial is pressed, the reference point is selected in the sequence of "end point 
1→end point 2→reference point on the line→•••" 
 
Reference point on the line 
 
 
 
As a result of the selection, the 
distance from the reference 
point to the end point 1 on the 
As a result of the selection, the 
distance from the reference 
point to the end point 2 on the 
As a result of selection, the 
interval from the reference point 
to the index line changes. 
 
 
4.6.7.3  Operation in [Track] mode 
The index lines of the group that is selected in [Group] combo box are operated in [Track] mode. 
 
[Operating the [EBL] dial] 
By using the [EBL] dial, the bearing of the index lines can be changed. 
 
[Operating the [VRM] dial] 
By using the [VRM] dial, the interval of the index lines can be changed. 
   
Reference point on the line