15-19  Section 15 Maintenance & Inspection 
 
 
 
 
 
15.5  Replacement of Major Parts 
The system includes parts that need periodic replacement. The parts should be replaced as scheduled.   
Use of parts over their service life can cause a system failure. 
 
 
Turn off the main power source before inspecting and replacing parts. 
Otherwise, an electric shock or trouble may be caused. 
 
15.5.1  Parts expected for periodic replacement 
Here are parts expected for periodic replacement. 
 
Part type  Name  Part name  Life expectancy 
Replacement   
kit type 
NKE-1130  S band radar  Magnetron  4,000 hours  CMG348 
Motor  10,000 hours  MDBW10823 
FAN for motor driver 
circuit 
20,000 hours  7BFRD0002 
FAN for modulation 
20,000 hours  5BFAB00674 
NKE-2255  X band radar 
FAN for 
20,000 hours  7BFRD0011 
NKE-2255-HS  X band radar 
FAN for 
20,000 hours  7BFRD0011 
NKE-2103  X band radar 
NKE-2103-HS  X band radar  Magnetron  4,000 hours  5VMAA00102 
NKE-1632  Solid state 
radar antenna 
FAN  100,000 hours  109L0912S410 
NKE-2632  Solid state 
radar antenna 
FAN  100,000 hours  109L0912S410 
NKE-2632-H 
Solid state 
radar antenna 
FAN  100,000 hours  109L0912S410 
*When the estimated replacement time arrives, a message urging the replacement will be displayed.