Section 4 Range and Bearing Measurement Methods  4-16 
4.6.3  Setting all the parallel index lines concurrently 
(All mode) 
When the operation mode is set to [All], all the parallel index lines are operated concurrently. All the 
lines are in parallel. 
 
1  Select [All] from the [Mode] combo box. 
2  Enter a direction of the parallel index lines in [PI Bearing] (parallel index line bearing). 
The setting is applied to the bearings of all the parallel index lines. 
The bearing can also be adjusted by turning the [EBL] dial clockwise/counterclockwise. 
When the dial is turned clockwise, the bearing is adjusted in the plus direction, and when 
the dial is turned counterclockwise, the bearing is adjusted in the minus direction.   
The set value is displayed in the input box. 
3  Enter a display interval of the parallel index lines in 09. [Interval]. 
The setting is applied to all the lines. 
The input range is the PPI radius when PPI is used as the centre for the lines and double the PPI 
radius when the PPI is not used as the centre. 
 
Memo 
The interval can also be adjusted by turning the [VRM] dial clockwise or anti-clockwise. If 
the dial is turned clockwise, the interval value increases and if 
anti-clockwise, the interval value decreases. 
The set value is displayed in the input box. 
 
Whenever the unit display switching button on the right side of [Interval] is clicked on, the unit 
(NM/km/sm) of the value displayed is switched. 
 
NM denotes nautical mile, sm denotes statute mile, and km denotes kilometre. 
4  Select the area for displaying the parallel index line from the [Operation Area] combo 
box. 
When [One Side] is selected, 8 parallel index lines are displayed on one side of the reference 
point of own ship or the point set arbitrarily. 
When [Both Side] is selected, 15 parallel index lines are displayed on both sides of the reference 
point of own ship or the point set arbitrarily.