Section 15 Maintenance & Inspection 15-16
1 Turn the [VRM] dial of the operation unit to the farthest edge of the performance
monitor pattern.
2 Check the amount of attenuation in the dialogue.
Benchmarks for the amount of attenuation are as follows:
Attenuation Value of Transmitter:
At normal: -6.9 dB to +2.0 dB
At degrading performances: -15.0 dB to -7.0 dB
Attenuation Value of Receiver:
At normal: -2.9 dB to +3.5 dB
At degrading performances: -15.0 dB to -3.0 dB
Memo
When confirming the attenuation value of the transmitter, after opening the dialogue, wait for
one minute, and then read its value.
If the attenuation value of the transmitter is -7 dB or lesser, or the receivers attenuation
indicator is -3 dB or lesser, it indicates that performances of the transmitter/receiver unit are
degrading.
In this case, inspection by the specialized service personnel is required. Contact our dealer, the
nearest service representative or JRC sales.