EasyManuals Logo

JUKI SC-910N Engineer's Manual

JUKI SC-910N
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
– 20 –
5. Error record display
Press error record display switch in the sewing management information screen (maintenance personnel
level). (Refer to the previous page.)
Error record screen
6. Communication mode
Uploading and downloading of various data with the sewing machine server utility (hereinafter called SU- 1) or
the compact flash (TM) can be performed in the communication mode.
For the communication mode, there are the operator level and the maintenance personnel level.
The kind of data which can be handled with the operator level is different from that with the maintenance person-
nel level.
Record No.
Error No.
Time occurred (Unit : time)
When switch or is pressed, the error record scrolls up or down.
Explanation of display
Error record of approximately 100 cases (depending on the memory capacity) can be stored in memory in the
order of the latest.
Kind of data Operation level Download Upload Extension Remarks
of file
Maintenance MSP
All sewing machine personnel
data
Panel Maintenance NG PRG
personnel
Main
Servo motor
Each program data
Communication function table
: Panel
: Compact flash (TM)
: SU-1

Table of Contents