– 27 –
ENGLISH
60
Function of stop
immediately after
reverse feed
stitching at the
start of sewing
Function at the time of completion of reverse feed stitching at
the start of sewing
0 : Not provided with the function of temporary stop of the
sewing machine at the time of completion of reverse feed
stitching at the start of sewing
1 : Provided with the function of temporary stop of the sew-
ing machine at the time of completion of reverse feed
stitching at the start of sewing.
0/1
6 0 0
37
61
Function
of starting
prohibition of the
sewing machine
by detection of
bobbin thread
remaining amount
Function of starting prohibition of the sewing machine by detec-
tion of bobbin thread remaining amount
0 : This function does not stop the sewing machine when
counting is out (-1 or less).
1 : This function stops the sewing machine when counting is
out (-1 or less).
0/1
6 1 1
36
*
64
Change-
over speed of
condensation
stitch or EBT (end
back tack)
Initial speed when starting condensation stitch or EBT
0 to 250
(r.p.m.)
6 4 1 8 0
*
65
On-timing of
solenoid for
condensation
stitch (when
condensation
stitch is performed
by 1 stitch.)
Starting (compensation) timing of solenoid for compensation
stitch : -1
Compensation value of starting the solenoid when condensation
stitch is performed by 1 stitch.
– 36 to 0
(10°)
6 5 – 1 5
32
*
66
On-timing of
solenoid for
condensation
stitch (when
condensation
stitch is performed
by 2 stitches.)
Starting (compensation) timing of solenoid for condensation
stitch : -2
Compensation value of starting the solenoid when condensation
stitch is performed by 2 stitches.
– 36 to 0
(10°)
6 6 – 1 5
32
67
Presser foot
lifting solenoid
output duty
setting
Duty of presser foot lifting solenoid output
5 to 40
6 7 2 0
37
68
Separately
driven needle
changeover
speed-up
function
Speed of separately driven needle changeover is set to high-
speed.
0 : Standard
1 : High-speed
0/1
6 8 0
70
Function of soft-
down of presser
foot
Presser foot is slowly lowered.
0 : Presser foot is rapidly lowered.
1 : Presser foot is slowly lowered.
0/1
7 0 0
37
71
Function of
limitation of re-
acceleration
from reduction of
speed
Speed limitation is performed at the time of re-acceleration on
the way of
reducing speed of the sewing machine.
It is effective when operating inching sewing.
0 to 5
7 1 0
37
72
Function of
limitation of
acceleration at the
start of rotation
Speed limitation is performed at the time of start-up of the sew-
ing machine (excluding the start of sewing).
It is effective when operating inching sewing.
0 to 5
7 2 0
37
73
Retry function
This function is used when needle cannot pierce materials .
0 : Normal
1 : Retry function is provided.
0/1
7 3 1
38
*
75
Rotating direction
of motor
Normal rotating direction of motor
0 : Clockwise
1 : Counterclockwise
0/1
7 5 0
76
Function to select
the start-up speed
of the sewing
machine
Starting curve of the sewing machine is selected.
0 : Normal curve
1 : More sharp curve
0/1
7 6 0
38
84
Initial motion suc-
tion time of presser
foot lifting solenoid
Suction motion time of presser foot lifting solenoid
40 to 300
(ms)
8 4 1 0 0
38
87
Function of pedal
curve selection
Pedal curve is selected. (Improving pedal inching operation)
0
/
1
/
2
8 7 0
38
No
Item Description
Setting range
Indication of function setting
Ref. page
*
Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the
time of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
If it is necessary to change the set value, please purchase the Engineer’s Manual and follow the instructions.
(Descriptions of setting in this list are the standard values at the time of delivery of DDL-9000A.)
However, contents of function setting are subject to change for improvement of function and performance without notice.
Items with mark are displayed when the machine heads of LH-4168, LH-4168D and LH-4188 are selected.
Number of rotations
Pedal stroke
2
0
1