Maintenance Guide
4-6. Replacement and adjustment of shutter sensor
Replace the sensor after moving the Z-axis to a convenient position for easy sensor replacement,
using 10. Z JOGof test mode.
When the replacement is finished, confirm that the shutter sensor turns ON.
Shutter open sensor (part No.: HD00057000A)
Shutter close sensor (part No.: HD00057000A)