Maintenance Guide
4-25. Replacement and adjustment of inspection transfer stop sensor
(transfer inspection specification: optional)
Replace the sensor, and make adjustment of sensitivity control knob.
Set the sensitivity control knob to 1/2.
Confirm that LED keeps unlit if no PWB is present but keeps lighting if a PWB is present in the
above condition.
EXAM stop sensor ASM (part No.: 40045196)
MIN
MAX
感度ボ
Sensitivity control knob