E 25
0606.GB
7.4 Troubleshooting
This chapter is designed to help the user identify and rectify basic faults or the results
of incorrect operation. When locating a fault, proceed in the order shown in the table.
Z
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer’s service department, as any further troubleshooting can only be
performed by specially trained and qualified service personnel.
Fault Possible cause Action
Truck does not
start.
– Battery plug not connected. – Check the battery plug and
connect if necessary.
– Key switch in "0" position – Set key switch to "I"
– Incorrect CANCODE code – Check code
– Battery charge too low. – Check battery charge, charge
battery if necessary
– Tiller not set to travel range (F) – Set tiller to travel range (F)
– Faulty fuse. – Check fuses F1 and F15
– On board charger connected – Disconnect on board charger
from mains
Load cannot
be lifted
– Truck not operational – Carry out all remedial actions
listed under “Truck does not
start”.
– Hydraulic oil level too low – Check the hydraulic oil level
– Faulty fuse. – Check fuse F15
– Load is too heavy – Note maximum capacity (see
data plate)
– Charge capacity below
20 / 40%
– Charge the battery
E 25
0606.GB
7.4 Troubleshooting
This chapter is designed to help the user identify and rectify basic faults or the results
of incorrect operation. When locating a fault, proceed in the order shown in the table.
Z
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer’s service department, as any further troubleshooting can only be
performed by specially trained and qualified service personnel.
Fault Possible cause Action
Truck does not
start.
– Battery plug not connected. – Check the battery plug and
connect if necessary.
– Key switch in "0" position – Set key switch to "I"
– Incorrect CANCODE code – Check code
– Battery charge too low. – Check battery charge, charge
battery if necessary
– Tiller not set to travel range (F) – Set tiller to travel range (F)
– Faulty fuse. – Check fuses F1 and F15
– On board charger connected – Disconnect on board charger
from mains
Load cannot
be lifted
– Truck not operational – Carry out all remedial actions
listed under “Truck does not
start”.
– Hydraulic oil level too low – Check the hydraulic oil level
– Faulty fuse. – Check fuse F15
– Load is too heavy – Note maximum capacity (see
data plate)
– Charge capacity below
20 / 40%
– Charge the battery