(degrees C) (degrees C) (degrees C) (degrees C)
Item Normal High Normal Bad fan Normal Bad fan Normal
Chassis default 48 54 65 55 80 65 100
Routing Engine 0 70 80 95 95 110 110 112
FPC 3 55 60 75 65 105 80 110
FPC 5 55 60 75 65 90 80 95
Table 44 on page 208 lists the output elds for the show chassis temperature-thresholds command. The
table lists output elds in the approximate order in which they appear.
Table 44: show chassis temperature-thresholds Output Fields
Field Name Field Descripon
Item Chassis component. You can congure the threshold informaon
for components such as the chassis, the Roung Engines, and FPC
for each slot in each FRU to display in the output. By default,
informaon is displayed only for the chassis and the Roung
Engines.
Fan speed Temperature thresholds, in degrees Celsius, for the fans to operate
at normal and at high speed.
NormalThe temperature threshold at which the fans operate
at normal speed and when all the fans are present and
funconing normally.
HighThe temperature threshold at which the fans operate at
high speed or when a fan has failed or is missing.
NOTE: An alarm is triggered when the temperature exceeds the
threshold sengs for a yellow, amber, or red alarm.
Yellow or amber alarm Temperature threshold, in degrees Celsius, that triggers a yellow or
amber alarm.
NormalThe temperature threshold that must be exceeded on
the device to trigger a yellow or amber alarm when the fans are
running at full speed.
Bad fanThe temperature threshold that must be exceeded on
the device to trigger a yellow or amber alarm when one or more
fans have failed or are missing.
208

Table of Contents

Other manuals for Juniper EX4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4100 and is the answer not in the manual?

Juniper EX4100 Specifications

General IconGeneral
ModelEX4100
CategorySwitch
LayerLayer 2/3
Power ConsumptionVaries by model and configuration
PoEOptional
ManagementWeb UI, CLI, SNMP
Operating Temperature0°C to 45°C
Input Voltage100-240V AC
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing
DC Power Input-48V DC
JUNOS OSYes
Security FeaturesACLs
Layer 2 FeaturesVLAN, RSTP, MSTP, LACP
Layer 3 FeaturesStatic routing, OSPF
QoS8 queues per port