user@host# edit chassis
2.
Enable configuration of a DPC (and its corresponding Packet Forwarding Engines) or
an FPC (and its installed PICs):
[edit chassis]
user@host# edit fpc slot-number
3.
Bind a named instance of Layer 2 port mirroring (pm-instance-name) to the DPC or
FPC:
[edit chassis fpc slot-number]
user@host# set port-mirror-instance pm-instance-name
4. (Optional) To bind a second named instance of Layer 2 port mirroring to the same
DPC or FPC, repeat step 3 and specify a different named instance of Layer 2 port
mirroring.
5.
Verify the minimum configuration of the binding:
[edit chassis fpc slot-number port-mirror-instance pm-instance-name]
user@host# top
[edit]
user@host# show chassis
chassis {
fpc slot-number { # Bind two port mirroring named instances at the FPC level.
port-mirror-instance pm-instance-name-1;
port-mirror-instance pm-instance-name-2;
}
}
Related
Documentation
Understanding Layer 2 Port Mirroring on page 3•
• Layer 2 Port Mirroring Named Instances
• Defining a Named Instance of Layer 2 Port Mirroring
• Binding Layer 2 Port Mirroring to Ports Grouped at the PIC Level on page 32
• Examples: Layer 2 Port Mirroring at Multiple Levels of the Chassis on page 34
• Example: Layer 2 Port Mirroring with Multiple Instances
31Copyright © 2016, Juniper Networks, Inc.
Chapter 6: Port Mirroring for Physical Interfaces