Figure 30: SRX5K-MPC3-40G10G
If a slot in the SRX5400, SRX5600, or SRX5800 Services Gateway card cage is not occupied by a card,
you must install a blank panel to shield the empty slot and to allow cooling air to circulate properly through
the services gateway.
Fixed-configuration MPC with six 40-Gigabit Ethernet ports and twenty-four 10-Gigabit
Ethernet ports
Maximum throughput: 240 Gbps
Maximum configurable MTU: 9192 bytes
Description
Junos OS Release 15.1X49-D10 and laterSoftware release
SRX5400 Any slot, except the bottom slot 0 which is reserved for SCB/RE.
SRX5600 Any slot, except the bottom slots 0 or 1 which are reserved for SCB/RE.
SRX5800 Any slot, except the middle slots 0, 1, and 2/6 which are reserved for SCB/RE
and slots 0 (left most) and 11 (right most).
NOTE: You can use the 2/6 slot to install an interface card if an SCB is not already installed
in it.
Supported Slots
Sockets for 40-Gbps and 10-Gbps SFP+ transceivers
See Hardware Compatibility Tool for the transceivers supported.
Cables and connectors
Typical: 9.68 A @ 48 V (460 W)
At different temperatures:
55° C: 607 W
40° C: 541 W
25° C: 511 W
Power requirements
21 lb (9.52 kg)Weight