Figure 32: SRX5K-MPC3-100G10G
If a slot in the SRX5400, SRX5600, or SRX5800 Services Gateway card cage is not occupied by a card,
you must install a blank panel to shield the empty slot and to allow cooling air to circulate properly through
the services gateway.
•
Fixed-configuration MPC with two 100-Gigabit Ethernet ports and four 10-Gigabit
Ethernet ports
•
Maximum throughput: 240 Gbps
•
Maximum configurable MTU: 9192 bytes
Description
Junos OS Release 15.1X49-D10 and laterSoftware release
•
SRX5400 – Any slot, except the bottom slot 0 which is reserved for SCB/RE.
•
SRX5600 – Any slot, except the bottom slots 0 or 1 which are reserved for SCB/RE.
•
SRX5800 – Any slot, except the middle slots 0, 1, and 2/6 which are reserved for SCB/RE
and slots 0 (left most) and 11 (right most).
NOTE: You can use the 2/6 slot to install an interface card if an SCB is not already
installed in it.
Supported Slots
Sockets for 100-Gbps and 10-Gbps SFP+ transceivers
See Hardware Compatibility Tool for the transceivers supported.
Cables and connectors
•
Typical: 10.52 A @ 48 V (505 W)
At different temperatures:
•
55° C: 607 W
•
40° C: 541 W
•
25° C: 511 W
Power requirements
21 lb (9.52 kg)Weight