Item Function and Setting
IN
POLARITY
For setting the polarity of the AUX input signal.
[Setting values: MAKE, BREAK] (Default value: MAKE)
MAKE : Inputs alarm when the contact of the AUX
and GND terminals switches from open to
close.
BREAK : Inputs alarm when the contact of the AUX
and GND terminals switches from close to
open.
Memo
When [AUX FUNCTION] is set to
“OUT:ALARM” or “OUT:B&W”, “---” is
displayed and [IN POLARITY] cannot be set.
OUT
POLARITY
For setting the polarity of the AUX output signal.
[Setting values: MAKE, BREAK] (Default value: MAKE)
MAKE : Contact is short when an alarm is initiated.
Contact is open when there is no alarm.
BREAK : Contact is open when an alarm is initiated.
Contact is short when there is no alarm.
Memo
When [AUX FUNCTION] is set to “IN:ALARM”
or “IN:SCENE A to IN:SCENE H”, “---” is
displayed and [OUT POLARITY] cannot be
set.
Menu Settings